LOGO
Search
Submit
Cancel
这是描述信息
/
/
/
/
DNA Library Prep - for MGI®

NGS Library Prep kits

Molecular Research

Drug Discovery

DNA Library Prep - for MGI®

794.00
Article number:
NDM607-01/02
VAHTS® Universal DNA Library Prep Kit for MGI is a library construction kit optimized for the MGI high-throughput sequencing platform. This kit can convert 100 pg-4 μg Input DNA into a library dedicated to MGI high-throughput sequencing platform. As a new upgraded version, VAHTS® Universal DNA Library Prep Kit for MGI greatly improves the library conversion rate and amplified library output through the overall improvement of the end repair module, the connection module and the library amplification module. It is widely applicable to a variety of Construction of PCR library of samples. All reagents provided in the kit have undergone strict quality control and functional verification, ensuring the stability and reproducibility of library construction to the greatest extent.   Efficient repair of DNA damage: effective repair of base damage, nicks, gaps and 3’ end closures High library construction efficiency: both library conversion rate and amplification output are improved Wide template compatibility: compatible with samples such as gDNA, FFPE DNA, cfDNA, Amplicons, etc. Perfect compatibility with different quality samples: DNA repair enzymes have excellent performance on FFPE DNA with different DIN values Short time-consuming library construction: the shortest single library construction only takes 90 minutes      Store at -30 ~ -15℃. Can be transported at -20 ~ 0℃
794.00
Article number:
NDM607-01/02
Number of views:
1668
Keywords:
vahts
library
the
dna
of
and
construction
kit
mgi
repair
908.00
Article number:
NDM617-01/02
VAHTS® Universal Plus DNA Library Prep Kit for MGI is a DNA library construction kit developed for the MGI high-throughput sequencing platform. This kit combines DNA fragmentation, end repair and dA tailing into one step. The product does not need to be purified. It is directly connected to adapters, library enriched and sorted, and can convert 100 pg-1 μg of template DNA into MGI high-throughput The library dedicated to the sequencing platform does not require mechanical interruption of the genome, which simplifies the library construction process and shortens the operation time, and is suitable for PCR library construction. This kit is perfectly compatible with DNA from different sources and different input amounts, and only needs to adjust the fragmentation time according to the size of the target insert to obtain the required library. All reagents provided in the kit have undergone strict quality control and functional verification to ensure the stability and reproducibility of library construction to the greatest extent.    Store at -30 ~ -15℃. Can be transported at -20 ~ 0℃
908.00
Article number:
NDM617-01/02
Number of views:
1528
Keywords:
vahts
the
and
to
library
dna
kit
is
of
mgi
1315.00
Article number:
NM108-01/02
VAHTS® DNA Adapters set8 for MGI is a special kit for BGI high-throughput sequencing platform library construction, suitable for BGI high-throughput sequencing platform multi-sample DNA library construction. The set 8 kit (NM108) contains 96 different Index connectors. All adapters provided in the kit have undergone strict quality control and functional verification to ensure the stability and reproducibility of library construction to the greatest extent.   Provide 24 kinds of Index tags; Strict quality control and functional verification of each batch    Store at -30 ~ -15℃.
1315.00
Article number:
NM108-01/02
Number of views:
1463
Keywords:
vahts
the
for
library
and
kit
of
sequencing
dna
strict
822.00
Article number:
NDM608-01/02
VAHTS® Universal Pro DNA Library Prep Kit for MGI is a MGI high-throughput sequencing platform library construction kit containing FFPE DNA repair module, which can convert 100 pg – 1 μg Input DNA into a library dedicated to the BGI platform. This kit contains a DNA damage repair module, which can effectively repair the DNA damage caused by formalin-fixed paraffin embedding (FFPE), such as cytosine deamination, nicking and nicking, base oxidation, 3'end blocking, etc. Compatible with ordinary DNA samples and does not affect the quality of the library of normal DNA samples. Through the overall improvement of the end repair module, the connection module and the library amplification module, the library conversion rate and the output of the amplified library are greatly improved, which is widely applicable to library construction of various samples and is compatible with the targeted capture process. All reagents provided in the kit have undergone strict quality control and functional verification to ensure the stability and reproducibility of library construction to the greatest extent.   Wide compatibility: easily cope with different species sources, different starting amounts, and different template types Simple operation: only need to adjust the fragmentation time according to the target insert size to get the required library High library yield: excellent library conversion rate and better sample quality      Store at -30 ~ -15℃.
822.00
Article number:
NDM608-01/02
Number of views:
1542
Keywords:
vahts
the
library
and
dna
to
of
module
repair
kit

The products on this website may not be sold in all countries or regions. Please contact Vazyme or your local distributor for further information.

这是描述信息

Add:Nanjing State Economy & Technology Development Zone, Red Maple Technology Industrial Park, building C 1-2 Tel:400-600-9335
Copyright 2015 Vazyme Biotech Co.,Ltd All rights reserved 
苏ICP备12014779号  Power by: www.300.cn nanjing.300.cn