LOGO
Search
Submit
Cancel
这是描述信息

NGS Library Prep kits

Molecular Research

Drug Discovery

library Quantification

93.00
Article number:
EQ121-01/02
93.00
Article number:
EQ121-01/02
Number of views:
1880
Keywords:
99.00
Article number:
EQ111-01/02
99.00
Article number:
EQ111-01/02
Number of views:
3295
Keywords:
EqualbitTM dsDNA HS Assay Kit
EQ111
129.00
Article number:
EQ211-01/02
Equalbit® RNA HS Assay Kit EqualbitTM RNA HS (High Sensitivity) Assay Kit is a simple, sensitive and accurate RNA fluorescence quantitative detection kit. This kit contains fluorescence detection reagents, buffers and RNA standards. The kit is highly selective for RNA and is not affected by dsDNA. It has an excellent linear relationship with RNA samples in the range of 5 to 100 ng. It can be used for total RNA, rRNA, and rRNA at a concentration of 250 pg/µl to 100 ng/µl. The mRNA samples are accurately quantified and have excellent tolerance to some conventional contaminants such as salt, free nucleotides, proteins, solvents, detergents, etc. This product is easy to operate and can be carried out at room temperature. Before use, the fluorescence detection reagent is diluted with a buffer solution into a working solution, and then the RNA sample to be tested is added to the Qubit® Fluorometer for detection.   Accurate sensitivity: It can accurately quantify total RNA, rRNA, and mRNA samples with a concentration of 1 ng/µl to 1000 ng/µl; Ultra-high specificity: This product is highly selective for RNA, not affected by DNA, and is excellent for some conventional pollutants, such as salt, free nucleotides, proteins, solvents, detergents, etc. Tolerance Operational simplicity: This product is easy to operate. The fluorescence detection reagents are diluted with buffer solution into working solution, and then the RNA sample to be tested is added to the Qubit® Fluorometer for detection. This operation can be performed at room temperature.    The complete kit should be stored at 2~8℃, protected from light; after the first use, Equalbit RNA HS Reagent is recommended to be stored at room temperature and protected from light; Equalbit RNA HS Buffer should be stored at room temperature; Equalbit RNA HS Standard #1 and #2 should be stored at 2 ~ 8℃
129.00
Article number:
EQ211-01/02
Number of views:
2121
Keywords:
Equalbit RNA HS Assay Kit
EQ211-01/02
129.00
Article number:
EQ212-01/02
Equalbit® RNA BR Assay Kit EqualbitTM RNA BR (Broad-Range) Assay Kit is a simple, sensitive and accurate RNA fluorescence quantitative detection kit. This kit contains fluorescence detection reagents, buffers and RNA standards. The kit is highly selective for RNA and is not affected by dsDNA. It has an excellent linear relationship with RNA samples in the range of 20 to 1000 ng, and can be used for total RNA, rRNA, and rRNA with concentrations ranging from 1 ng/µl to 1000 ng/µl. The mRNA samples are accurately quantified and have excellent tolerance to some conventional contaminants such as salt, free nucleotides, proteins, solvents, detergents, etc. This product is easy to operate and can be carried out at room temperature. Before use, the fluorescence detection reagent is diluted with a buffer solution into a working solution, and then the RNA sample to be tested is added to the Qubit® Fluorometer for detection.   Simple and easy to operate Ready-to-use premix, no need to prepare working fluid, simplifying operation steps Ultra-high sensitivity, accurate quantification of 0.2-100 ng dsDNA Super specificity It detects dsDNA specifically and has excellent tolerance to some conventional pollutants Fast dye binding speed can reach saturation within 2 minutes Extremely high stability Strictly control the production process of standard products to ensure stability between batches   The complete kit should be stored at 2~8℃, protected from light; after the first use, Equalbit RNA BR Reagent is recommended to be stored at room temperature and protected from light; Equalbit RNA BR Buffer should be stored at room temperature; Equalbit RNA BR Standard #1 and #2 should be stored at 2 ~ 8℃
129.00
Article number:
EQ212-01/02
Number of views:
1816
Keywords:
Equalbit RNA BR Assay Kit
EQ212-01/02
596.00
Article number:
NQ201
This product is a special kit for the concentration determination of high-throughput sequencing libraries on the Illumina® platform using the dye qPCR method. The working principle is to draw a standard curve using standard products, and then calculate the absolute concentration of the library to be tested based on the standard curve. The kit uses a new dye-based qPCR premix VAHTSTM SYBR® qPCR Master Mix based on antibody hot start. This premix has many advantages such as high specificity, high amplification efficiency, wide adaptability of GC content, high detection sensitivity, etc., and is very suitable for absolute quantification of library concentration. All reagents provided in the kit have undergone strict quality control to ensure the reproducibility of experimental results between different batches to the greatest extent.   Include all necessary components for absolute quantification; New dye method qPCR master mix VAHTSTM SYBR® qPCR Master Mix; High amplification efficiency and good GC content compatibility; The standard product is quantified accurately, and the CV value between batches is <5%; Carefully optimized ROX dye concentration, ROX premixed version is available; Compatible with all mainstream quantitative PCR machines   All components should be stored at -20°C, Master Mix and ROX should be protected from light
596.00
Article number:
NQ201
Number of views:
1621
Keywords:
vahts
the
is
and
of
qpcr
mix
to
standard
high
72.00
Article number:
NQ106
This product is a special kit for the concentration determination of high-throughput sequencing libraries on the Illumina® platform using the dye qPCR method. The working principle is to draw a standard curve using standard products, and then calculate the absolute concentration of the library to be tested based on the standard curve. The kit uses a new dye-based qPCR premix VAHTSTM SYBR® qPCR Master Mix based on antibody hot start. This premix has many advantages such as high specificity, high amplification efficiency, wide adaptability of GC content, high detection sensitivity, etc., and is very suitable for absolute quantification of library concentration. All reagents provided in the kit have undergone strict quality control to ensure the reproducibility of experimental results between different batches to the greatest extent.   Accurate sensitivity: accurate quantification of dsDNA samples with a concentration of 10 pg/µl to 100 ng/µl; Ultra-high specificity: This product has a high degree of selectivity for double-stranded DNA, is not affected by RNA, and has some conventional pollutants, such as salt, free nucleotides, proteins, solvents, detergents, etc. Excellent tolerance; Convenience of operation: This product is easy to operate. The fluorescence detection reagent is diluted with a buffer solution into a working solution, and then the dsDNA sample to be tested is added to the Qubit® Fluorometer for detection. This operation can be performed at room temperature.    All components should be stored at -20°C, Master Mix and ROX should be protected from light
72.00
Article number:
NQ106
Number of views:
1648
Keywords:
library
the
of
to
is
be
this
and
high
for
326.00
Article number:
NQ105
This product is a special kit for the concentration determination of high-throughput sequencing libraries on the Illumina® platform using the dye qPCR method. The working principle is to draw a standard curve using standard products, and then calculate the absolute concentration of the library to be tested based on the standard curve. The kit uses a new dye-based qPCR premix VAHTSTM SYBR® qPCR Master Mix based on antibody hot start. This premix has many advantages such as high specificity, high amplification efficiency, wide adaptability of GC content, high detection sensitivity, etc., and is very suitable for absolute quantification of library concentration. All reagents provided in the kit have undergone strict quality control to ensure the reproducibility of experimental results between different batches to the greatest extent.   Accurate sensitivity: accurate quantification of dsDNA samples with a concentration of 10 pg/µl to 100 ng/µl; Ultra-high specificity: This product has a high degree of selectivity for double-stranded DNA, is not affected by RNA, and has some conventional pollutants, such as salt, free nucleotides, proteins, solvents, detergents, etc. Excellent tolerance; Convenience of operation: This product is easy to operate. The fluorescence detection reagent is diluted with a buffer solution into a working solution, and then the dsDNA sample to be tested is added to the Qubit® Fluorometer for detection. This operation can be performed at room temperature.    All components should be stored at -20°C, Master Mix and ROX should be protected from light
326.00
Article number:
NQ105
Number of views:
1977
Keywords:
standard
the
of
to
is
be
this
and
high
for
239.00
Article number:
NQ101/102/103/104
This product is a special kit for the concentration determination of high-throughput sequencing libraries on the Illumina® platform using the dye qPCR method. The working principle is to draw a standard curve using standard products, and then calculate the absolute concentration of the library to be tested based on the standard curve. The kit uses a new dye-based qPCR premix VAHTSTM SYBR® qPCR Master Mix based on antibody hot start. This premix has many advantages such as high specificity, high amplification efficiency, wide adaptability of GC content, high detection sensitivity, etc., and is very suitable for absolute quantification of library concentration. All reagents provided in the kit have undergone strict quality control to ensure the reproducibility of experimental results between different batches to the greatest extent.   Include all necessary components for absolute quantification; New dye method qPCR master mix VAHTSTM SYBR® qPCR Master Mix; High amplification efficiency and good GC content compatibility; The standard product is quantified accurately, and the CV value between batches is <5%; Carefully optimized ROX dye concentration, ROX premixed version is available; Compatible with all mainstream quantitative PCR machines   All components should be stored at -20°C, Master Mix and ROX should be protected from light
239.00
Article number:
NQ101/102/103/104
Number of views:
3220
Keywords:
vahts
the
is
and
of
qpcr
mix
to
standard
high

The products on this website may not be sold in all countries or regions. Please contact Vazyme or your local distributor for further information.

这是描述信息

Add:Nanjing State Economy & Technology Development Zone, Red Maple Technology Industrial Park, building C 1-2 Tel:400-600-9335
Copyright 2015 Vazyme Biotech Co.,Ltd All rights reserved 
苏ICP备12014779号  Power by: www.300.cn nanjing.300.cn